Brachytherapy
Volume 8, Issue 4 , Pages 361-366 , October 2009

Bi- and tri-exponential fitting to TG-43 radial dose functions of brachytherapy sources based on a genetic algorithm

  • Xingen Wu

      Affiliations

    • Corresponding Author InformationCorresponding author. Department of Radiation Oncology, University of Alabama at Birmingham, 1824 6th Avenue South, WTI# 133, Birmingham, AL 35249. Tel.: +1-205-934-1489; fax: +1-205-975-2546.
  • ,
  • Ivan A. Brezovich
  • ,
  • John B. Fiveash

Received 20 August 2008 ,Revised 6 October 2008 ,Accepted 4 November 2008.

References 

  1. Rivard MJ, Coursey BM, DeWerd LA, et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys. 2004;31:633–674
  2. Duggan DM, Johnson BL. Dosimetry of the I-Plant 3500 iodine-125 brachytherapy source. Med Phys. 2001;18:661–670
  3. Furhang EE, Wallace RE. Fitting and benchmarking of dosimetry data for new brachytherapy sources. Med Phys. 2000;27:2302–2306
  4. Furhang EE, Anderson LL Functional fitting of interstitial bracytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43. American Association of Physicists in Medicine. Med Phys. 1999;26:153–160
  5. Moss DC. Improved analytical fit to the TG-43 radial dose function, g(r). Med Phys. 2000;27:659–661
  6. Nath R, Anderson LL, Luxton G, et al. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22:209–234
  7. Karaiskos P, Papagiannis P, Sakelliou L, et al. Monte Carlo dosimetry of the selectSeed 125I interstitial brachytherapy seed. Med Phys. 2001;28:1753–1760
  8. Wallace RE. Empirical dosimetric characterization of model I125-SL 125 iodine brachytherapy source in phantom. Med Phys. 2000;27:2796–2802
  9. Nath R, Yue N, Roa E. Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of Pd-103 Model Pd-1. Med Phys. 2002;29:2433–2434
  10. Reniers B, Vynckier S, Scalliet P. Dosimetric study of the new Intersource125 iodine seed. Med Phys. 2001;28:2285–2288
  11. Meigooni AS, Yoe-Sein MM, Al-Otoon AY, et al. Determination of the dosimetric characteristics of InterSource125 iodine brachytherapy source. Appl Radiat Isot. 2002;56:589–599
  12. Rivard MJ. Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the MED3631-A/M125I source. Med Phys. 2001;28:629–637
  13. Peterson SW, Thomadsen B. Measurements of the dosimetric constants for a new 103Pd brachytherapy source. Brachytherapy. 2002;1:110–119
  14. Kirov AS, Williamson JF. Monte Carlo-aided dosimetry of the Source Tach Medical I-125 interstitial brachytherapy seed. Med Phys. 2001;28:764–772
  15. Variseed version 7.1. Palo Alto, CA: Varian, 2003.

PII: S1538-4721(08)00675-2

doi: 10.1016/j.brachy.2008.11.005

Brachytherapy
Volume 8, Issue 4 , Pages 361-366 , October 2009