Brachytherapy
Volume 7, Issue 4 , Pages 320-326, October 2008

Concepts for critical organ dosimetry in three-dimensional image-based breast brachytherapy

Department of Radiotherapy, Medical University of Vienna, General Hospital of Vienna, Vienna, Austria

Received 10 April 2008; received in revised form 8 August 2008; accepted 8 August 2008.

Abstract 

Purpose

To investigate dose–volume histogram (DVH) parameters for organs at risk (OARs) in sectional three-dimensional image-based accelerated partial breast irradiation.

Methods and Materials

Skin, lung, and ribs were defined as OARs and the heart was discussed. Two different skin-contouring methods were tested on phantom before applying to the patient cohort. First, an inside skin wall contour was delineated with three different wall thicknesses to demonstrate the influence of contouring on DVH parameter. Second a structure was defined, delineated outside of the phantom surface, such that a three-dimensional skin volume was extended like a virtual bolus contour. Point dose values and DVH parameters were reported for 25 patient cases.

Results

The DVH parameters D0.1cc=65±21, D1cc=45±8, and D10cc=30±4cGy/pulse for the outside skin structure around the breast corresponded to skin surface areas of 1±1, 6±3, and 6±11cm2. Lung volume receiving 20Gyαβ3 was 8.3±11cm3. D0.1cc and D2cc in the most exposed rib were 0.7±0.3 and 0.4±0.2Gy/pulse, respectively.

Conclusion

In accelerated partial breast irradiation treatment planning, dose to OAR can be reported in a more sophisticated way with DVH parameters than using points only. The suggested method of skin delineation using the defined outside structure allows calculating reliable and reproducible DVH parameters.

Keywords: Brachytherapy, Breast, Organ at risk, Skin, Image-based dosimetry

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1538-4721(08)00606-5

doi:10.1016/j.brachy.2008.08.002

Brachytherapy