Brachytherapy
Volume 7, Issue 4 , Pages 327-335 , October 2008

The impact of prescription depth, dose rate, plaque size, and source loading on the central axis using 103Pd, 125I, and 131Cs

  • Mark J. Rivard

      Affiliations

    • Corresponding Author InformationCorresponding author. Department of Radiation Oncology, Box #246, Tufts Medical Center, 750 Washington Street, Boston, MA 02111, USA. Tel.: +1-617-636-1680; fax: +1-617-636-7621.
    • Mark J. Rivard is a consultant to IsoRay Medical of Richland, WA.
  • ,
  • Christopher S. Melhus
  • ,
  • Shirin Sioshansi
  • ,
  • Jody Morr

Received 27 November 2007 ,Revised 6 April 2008 ,Accepted 28 May 2008.

References 

  1. Nag S, Quivey JM, Earle JD, et al. The American Brachytherapy Society recommendations for brachytherapy of uveal melanomas. Int J Radiat Oncol Biol Phys. 2003;56:544–555
  2. Hawkins BS Collaborative Ocular Melanoma Study Group. The Collaborative Ocular Melanoma Study (COMS) randomized trial of pre-enucleation radiation of large chorodial melanoma: IV. Ten-year mortality findings and prognostic factors. COMS Report Number 24. Am J Ophthalmol. 2004;138:936–951
  3. Damato B. Treatment of primary intraocular melanoma. Expert Rev Anticancer Ther. 2006;6:493–506
  4. Margo CE. The Collaborative Ocular Melanoma Study: An overview. Cancer Control. 2004;11:304–309
  5. Finger PT. Radiation therapy for choroidal melanoma. Surv Ophthalmol. 1997;42:215–232
  6. Bedford MA, Bedotto C, MacFaul PA. Retinoblastoma: A study of 139 cases. Br J Ophthalmol. 1971;55:19–27
  7. Karlsson UL, Augsburger JJ, Shields JA, et al. Recurrence of posterior uveal melanoma after 60 Co episcleral plaque therapy. Ophthalmology. 1989;96:382–388
  8. Lommatzsch P. Treatment of choroidal melanomas with 106 Rh beta-ray applicators. Surv Ophthalmol. 1974;19:85
  9. Lommatzsch PK. Beta irradiation with 106Ru/106Rh applicators of choroidal melanomas: Sixteen years' experience. In:  Lommatzsch PK,  Blodi FC editor. Intraocular tumors. Berlin: Academie-Verlag; 1983;p. 290–301
  10. MacFaul PA, Morgan G. Histopathological changes in malignant melanomas of the choroid after cobalt plaque therapy. Br J Ophthalmol. 1977;61:221–228
  11. Markoe AM, Brady LW, Shields JA, et al. Radioactive eye-plaque therapy versus enucleation for the treatment of posterior uveal malignant melanoma. Radiology. 1985;156:801–803
  12. Muller RP, Busse H, Potter R, et al. Results of high dose 106-ruthenium irradiation of choroidal melanomas. Int J Radiat Oncol Biol Phys. 1986;12:1749–1755
  13. Packer S. Iodine-125 radiation of posterior uveal melanoma. Ophthalmology. 1987;94:1621–1626
  14. Stallard HB. Radiobiology for malignant melanoma of the choroid. Br J Ophthalmol. 1966;50:147–155
  15. Fontanesi J, Nag S. Brachytherapy for ocular disease. In:  Nag S editors. Principles and practice of brachytherapy. Armonk, NY: Future Publishing Company Inc; 1997;p. 291–304
  16. Fontanesi J, Meyer D. Treatment of large melanomas with split-plaque technique: Pilot experience. Endocuriether Hypertherm Oncol. 1995;11:9–13
  17. Rivard MJ, Coursey BM, DeWerd LA, et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys. 2004;31:633–674
  18. Rivard MJ, Butler WM, DeWerd LA, et al. Supplement to the 2004 update of the AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys. 2007;34:2187–2205
  19. Finger PT, Lu D, Buffa A, et al. Palladium-103 versus iodine-125 for ophthalmic plaque radiotherapy. Int J Radiat Oncol Biol Phys. 1993;27:849–854
  20. NUDAT 2.0, National Nuclear Data Center, Brookhaven National Laboratory. Available at: http://www.nndc.bnl.gov/nudat2/index.jsp. Accessed February 8, 2008.
  21. Monroe JI, Williamson JF. Monte Carlo-aided dosimetry of the Theragenics TheraSeed® Model 200 103Pd interstitial brachytherapy seed. Med Phys. 2002;29:609–621
  22. Taylor REP, Yegin G, Rogers DWO. Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters. Med Phys. 2007;34:445–457
  23. Dolan J, Li Z, Williamson JF. Monte Carlo and experimental dosimetry of an 125I brachytherapy seed. Med Phys. 2006;33:4675–4684
  24. Rivard MJ. Brachytherapy dosimetry parameters calculated for a 131Cs source. Med Phys. 2007;34:754–762
  25. Wittman RS, Fisher DR. Multiple-estimate Monte Carlo calculation of the dose rate constant for a cesium-131 interstitial brachytherapy seed. Med Phys. 2007;34:49–54
  26. Tailor RC, Ibbott GS, Lampe S, et al. Dosimetric characterization of a brachytherapy source by thermoluminescence dosimetry in liquid water. Med Phys 2008;35: In press.
  27. Sou-Tung Chiu-Tsao. Personnel communication, 28 March 2007.
  28. Astrahan MA, Szechter A, Finger PT. Design and dosimetric considerations of a modified COMS plaque: The reusable “seed-guide” insert. Med Phys. 2005;32:2706–2716
  29. Astrahan MA. Improved treatment planning for COMS eye plaques. Int J Radiat Oncol Biol Phys. 2005;61:1227–1242
  30. Freire JE, Kolton MM, Brady LW, et al. Eye and orbit. In:  Halperin EC editors. Perez and Brady's principles and practice of radiation oncology. 5th ed.. Philadelphia, PA: Lippincott, Williams, & Wilkins; 2008;p. 778–799
  31. Hermann RM, Pradier O, Lauritzen K, et al. Does escalation of the apical dose change treatment outcome in β-radiation of posterior choroidal melanomas with 106Ru plaques?. Int J Radiat Oncol Biol Phys. 2002;52:1360–1366
  32. Schueler AO, Flühs D, Anastassiou G, et al. β-Ray brachytherapy with 106Ru plaques for retinoblastoma. Int J Radiat Oncol Biol Phys. 2006;65:1212–1221
  33. Quivey JM, Char DH, Philips TL, et al. High intensity 125-iodine (125I) plaque treatment of uveal melanoma. Int J Radiat Oncol Biol Phys. 1993;26:613–618
  34. Finger PT, Berson A, Tracy N, et al. Palladium-103 plaque radiotherapy for choroidal melanoma: An 11 year study. Int J Radiat Oncol Biol Phys. 2002;54:1438–1445
  35. Chiu-Tsao S-T, Anderson LL, O'Brien K, et al. Dosimetry for 125I seed (model 6711) in eye plaques. Med Phys. 1993;20:383–389
  36. Garcia JP, Garcia PT, Rosen RB, et al. A 3-dimensional ultrasound C-scan imaging technique for optic nerve measurements. Ophthalmology. 2004;111:1238–1243

 This work was presented in part at the New England AAPM chapter meeting on 4 October 2007 in Boylston, MA.

PII: S1538-4721(08)00591-6

doi: 10.1016/j.brachy.2008.05.002

Brachytherapy
Volume 7, Issue 4 , Pages 327-335 , October 2008