Brachytherapy
Volume 5, Issue 1 , Pages 56-60 , January 2006

Quality assurance of treatment plans for interstitial and intracavitary high-dose-rate brachytherapy

Received 6 September 2005 ,Revised 11 November 2005 ,Accepted 18 November 2005.

References 

  1. Stitt JA, Fowler JF, Thomadsen BR, et al. High dose rate intracavitary brachytherapy for carcinoma of the cervix: The Madison system: I. Clinical and radiobiological considerations. Int J Radiat Oncol Biol Phys. 1992;24:335–348
  2. Clarke DH, Vicini FA, Jacobs H, et al. High dose rate brachytherapy for breast cancer. In:  Nag S editors. High dose rate brachytherapy: a textbook. Armonk, NY: Futura Publishing Co.; 1994;p. 321–329
  3. Kuske R, Bolton J, Wilenzick R, et al. Brachytherapy as the sole method of breast irradiation in Tis, T1, T2, N0, 1 breast cancer. (Abstr.) Int J Radiat Oncol Biol Phys. 1994;30:245
  4. Martinez AA, Pataki I, Edmunson G, et al. Interim report of image-guided conformal high-dose-rate brachytherapy as monotherapy for the treatment of favorable stage prostate cancer: A feasibility report. Int J Radiat Oncol Biol Phys. 2001;49:61–69
  5. Das RK, Thomadsen BR. High dose rate sources and delivery system. In:  Thomadsen BR, et al. editor. Brachytherapy physics. 2nd ed.. Madison, WI: Medical Physics Publishing Co.; 2005;p. 59–74
  6. U.S. Nuclear Regulatory Commission . Title 10, Chapter 1, Code of Federal Regulations—Energy. Part 35. Medical use of by-product material. Washington, DC: Government Printing Office; 2003;
  7. Williamson JF, Ezzell GA, Olan A, et al. Quality assurance for high dose rate brachytherapy. In:  Nag S editors. High dose rate brachytherapy: a textbook. Armonk, NY: Futura Publishing Co.; 1994;p. 147–212
  8. Kubo H, Chin RB. Simple mathematical formulas for quick-checking of single catheter high dose rate brachytherapy plans. Endocurie Hypertherm Oncol. 1992;8:165–169
  9. Thomadsen BR, Shahabi S, Stitt JA, et al. High dose rate intracavitary brachytherapy for carcinoma of the cervix: The Madison system: II. Procedural and physical considerations. Int J Radiat Oncol Biol Phys. 1992;24:349–357
  10. Paterson R, Parker HM. A dosage system for interstitial radium therapy. Br J Radiol. 1938;11:252–266313–340
  11. Das RK, Patel R, Shah H, et al. 3D CT–based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance. Int J Radiat Oncol Biol Phys. 2004;59:1224–1228
  12. Nath R, Anderson LL, Luxton G, et al. Dosimetric of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22:209–234
  13. Anderson LL. A natural volume–dose histogram for brachytherapy. Med Phys. 1986;13:898–903

PII: S1538-4721(05)00200-X

doi: 10.1016/j.brachy.2005.11.002

Brachytherapy
Volume 5, Issue 1 , Pages 56-60 , January 2006